Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.985
Filtrar
1.
Ann Plast Surg ; 92(4S Suppl 2): S80-S86, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556652

RESUMO

INTRODUCTION: Amid rising obesity, concurrent ventral hernia repair and panniculectomy procedures are increasing. Long-term outcomes of transverse abdominis release (TAR) combined with panniculectomy remain understudied. This study compares clinical outcomes and quality of life (QoL) after TAR, with or without panniculectomy. METHODS: A single-center retrospective review from 2016 to 2022 evaluated patients undergoing TAR with and without panniculectomy. Propensity-scored matching was based on age, body mass index, ASA, and ventral hernia working group. Patients with parastomal hernias were excluded. Patient/operative characteristics, postoperative outcomes, and QoL were analyzed. RESULTS: Fifty subjects were identified (25 per group) with a median follow-up of 48.8 months (interquartile range, 43-69.7 months). The median age and body mass index were 57 years (47-64 years) and 31.8 kg/m2 (28-36 kg/m2), respectively. The average hernia defect size was 354.5 cm2 ± 188.5 cm2. There were no significant differences in hernia recurrence, emergency visits, readmissions, or reoperations between groups. However, ventral hernia repair with TAR and panniculectomy demonstrated a significant increase in delayed healing (44% vs 4%, P < 0.05) and seromas (24% vs 4%, P < 0.05). Postoperative QoL improved significantly in both groups (P < 0.005) across multiple domains, which continued throughout the 4-year follow-up period. There were no significant differences in QoL among ventral hernia working group, wound class, surgical site occurrences, or surgical site occurrences requiring intervention (P > 0.05). Patients with concurrent panniculectomy demonstrated a significantly greater percentage change in overall scores and appearance scores. CONCLUSIONS: Ventral hernia repair with TAR and panniculectomy can be performed safely with low recurrence and complication rates at long-term follow-up. Despite increased short-term postoperative complications, patients have a significantly greater improvement in disease specific QoL.


Assuntos
Abdominoplastia , Hérnia Ventral , Lipectomia , Humanos , Qualidade de Vida , Hérnia Ventral/cirurgia , Abdominoplastia/métodos , Lipectomia/métodos , Complicações Pós-Operatórias/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Herniorrafia/métodos , Telas Cirúrgicas/efeitos adversos , Recidiva
2.
Ann Plast Surg ; 92(4S Suppl 2): S156-S160, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556666

RESUMO

INTRODUCTION: The ideal mesh type for hernia repair in a contaminated field remains controversial. Data regarding outcomes beyond 1 year and the impact on quality of life (QoL) are unknown. This study aims to evaluate the long-term surgical outcomes and patient-reported outcomes (PROs) after contaminated repair with poly-4-hydroxybutyrate (P4HB) mesh. MATERIALS METHODS: Patients undergoing a contaminated hernia repair with P4HB between 2015 and 2020 were identified. Surgical site occurrences and hernia recurrences were recorded. Long-term PROs as defined by the Abdominal Hernia-Q and Hernia-Related Quality-of-Life Survey were assessed. RESULTS: Fifty-five patients were included with a mean age of 54.5 years, a body mass index of 34 kg/m2, and a defect size of 356.9 ± 227.7 cm2. Median follow-up time was 49 months with a reoperation rate of 14.5% and a hernia recurrence rate of 7.3%. Of the 55 patients, 37 completed preoperative and postoperative PRO questionnaires. When comparing preoperative with postoperative Abdominal Hernia-Q, there was significant improvement in overall PROs (2.1 vs 3.5, P < 0.001). This improvement was maintained with no significant changes between postoperative scores over the course of 5 years. Patients with complications saw the same improvement in postoperative PRO scores as those without complications. CONCLUSIONS: Our study found a low hernia recurrence and acceptable long-term reoperation rates in patients undergoing hernia repair with P4HB mesh in a contaminated setting. We demonstrate a sustained significant improvement in QoL scores after hernia repair. These data yield insight into the long-term outcomes and QoL improvement, providing physicians further knowledge to better counsel their patients.


Assuntos
Hérnia Ventral , Hérnia Incisional , Humanos , Pessoa de Meia-Idade , Qualidade de Vida , Herniorrafia/efeitos adversos , Resultado do Tratamento , Infecção da Ferida Cirúrgica/etiologia , Telas Cirúrgicas/efeitos adversos , Hérnia Ventral/cirurgia , Hérnia Incisional/cirurgia , Recidiva , Estudos Retrospectivos
3.
BMJ Case Rep ; 17(4)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589247

RESUMO

Corona mortis (CM) is an anastomotic vessel between the inferior epigastric or external iliac vessels and the obturator or internal iliac vessels. The Latin meaning of it is 'crown of death' which corresponds to massive haemorrhage caused by injury to this vessel during surgery. The incidence of this vessel is around 50% in the hemipelvis. We are presenting an intraoperative video of a right laparoscopic totally extraperitoneal mesh hernioplasty demonstrating a CM artery in the right hemipelvis. Care was taken to prevent injury to this vessel. CO2 insufflation pressure was reduced to less than 10 mm Hg to see any venous variant of this vessel. Carefully, polypropylene mesh was placed without a fixation device. Anatomical knowledge of the CM vessel is therefore essential in preventing injury for surgeons who approach the inguinal and retropubic regions.


Assuntos
Hérnia Inguinal , Laparoscopia , Humanos , Artéria Ilíaca/cirurgia , Herniorrafia , Telas Cirúrgicas/efeitos adversos , Artérias/cirurgia , Hérnia Inguinal/cirurgia
4.
Chirurgia (Bucur) ; 119(1): 87-101, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38465719

RESUMO

Background: Chronic postoperative inguinal pain (CPIP) is still the most frequent complication after open Lichtenstein repair and any strategy to reduce its incidence and implications is a step forward to better outcomes. Between the means of mesh fixation atraumatic glue fixation has been explored as such possibility. A meta-analysis of randomized controlled trials comparing the performance of cyanoacrylate glue versus sutures fixation was conducted. Methods: the meta-analysis was conducted according to the PRISMA guidelines. Randomized controlled trials (RCTs) published between January 2000 and December 2021 were searched for in MEDLINE, PubMed, Web of Science, and Google Scholars. The quality of RCTs and the potential risk of bias were assessed using MINORS criteria and the Cochrane risk of bias tool. Results: of 269 papers the meta-analysis was performed on 19 RCTs including 3578 patients. In the glue fixation group, the operation was shorter (mean pooled difference 6 minutes; SE = 0.47; 95% CI = - 6.77 - - 4.92; t test = -12.36; p 0.0001) and immediate postoperative pain was lower (2.37% vs 13.3%OR - 0.158; 95% CI = 0.064 0.386; p = 0.0001). There was no difference in terms of chronic pain, recurrence rate and wound events. Conclusion: glue fixation of mesh in elective Lichtenstein repair of inguinal hernia seems to be a valid choice for a painful and safe procedure without increasing risk of recurrence.


Assuntos
Dor Crônica , Hérnia Inguinal , Humanos , Cianoacrilatos/uso terapêutico , Telas Cirúrgicas/efeitos adversos , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Dor Crônica/etiologia , Dor Crônica/prevenção & controle , Suturas/efeitos adversos , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Recidiva
5.
Surg Endosc ; 38(4): 2231-2239, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38498213

RESUMO

BACKGROUND: Biosynthetic meshes afford the cost advantages of being made from fully synthetic material, but are also biodegradable, making them a versatile option that can be used in both clean and contaminated cases. The aim of this study is to evaluate the safety profile and long-term outcomes of using GORE BIO-A (BIO-A) as an adjunct to abdominal wall reconstruction in all wound classes. METHODS: A retrospective review identified patients undergoing abdominal hernia repair using BIO-A from October 2008 to June 2018. The primary outcome was hernia recurrence rate. Only patients with at least 6-month follow-up were included when looking at recurrence rates. Secondary outcomes included 30-day morbidity categorized according to CDC Surgical Site Infection Criteria, return to operating/procedure room (RTOR), 30-day readmission, length of stay (LOS), and mortality. RESULTS: A total of 207 patients were identified, CDC Wound Classification breakdown was 127 (61.4%), 41 (19.8%), 14 (6.8%), and 25 (12.1%) for wound classes I, II, III, and IV, respectively. Median follow-up was 55.4 months (range 0.2-162.4). Overall recurrence rate was 17.4%. Contaminated cases experienced higher recurrence rates (28.8% versus 10.4%, p = 0.002) at a mean follow up of 46.9 and 60.8 months for contaminated and clean patients, respectively. Recurrent patients had higher BMI (32.4 versus 28.4 kg/m2, p = 0.0011), larger hernias (162.2 versus 106.7 cm2, p = 0.10), higher LOS (11.1 versus 5.6 days, p = 0.0051), and higher RTOR rates (16.7% versus 5.6%, p = 0.053). 51 (24.5%) patients experienced some morbidity, including 19 (9.2%) surgical site occurences, 7 (3.4%) superficial surgical site infections, 16 (7.7%) deep surgical site infections, and 1 (0.5%) organ space infection. CONCLUSION: This study affirms the use of biosynthetic mesh as a cost-effective alternative in all wound classifications, yielding good outcomes, limited long-term complications, and low recurrence. rates.


Assuntos
Hérnia Ventral , Infecção da Ferida Cirúrgica , Humanos , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/cirurgia , Resultado do Tratamento , Recidiva Local de Neoplasia/cirurgia , Hérnia Ventral/cirurgia , Hérnia Ventral/complicações , Estudos Retrospectivos , Deiscência da Ferida Operatória , Herniorrafia/métodos , Telas Cirúrgicas/efeitos adversos , Recidiva
6.
Eur J Obstet Gynecol Reprod Biol ; 296: 275-279, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38493551

RESUMO

OBJECTIVES: To report the results of a mesh-less laparoscopic extraperitoneal linear suspension technique for the treatment of post-hysterectomy vaginal vault prolapse (PHVP). STUDY DESIGN: A retrospective observational study was conducted collecting medical records of 41 patients with symptomatic PHVP treated between November 2017 to November 2019 in Gynecologic department of China-Japan Friendship Hospital. All patients had Pelvic Organ Prolapse Quantification (POP-Q) scores indicating stage 3-4 PHVP and underwent mesh-less laparoscopic extraperitoneal linear suspension.The primary outcome was the subjective satisfaction rate based on responses to validated questionnaires. The secondary outcomes were the objective anatomical cure rate based on POP-Q scores and complication rates. All listed parameters were determined before the surgery and at control examinations in 1 year and 3 years after the treatment. RESULTS: The operation was completed successfully without serious complications in all patients. Mean operation time was 53.8 mins. Comparison of the scores by the questionnaires revealed a significant improvement in the quality of life in the postoperative period.The subjective satisfaction rates were 100 % (41/41) and 95 % (38/40) at 1 year and 3 years after surgery. The objective cure rates were 100 % (41/41) and 97.5 % (39/40) at 1 year and 3 years after surgery, respectively. During the follow-up, none of the patients experienced suture exposure, infection, chronic pelvic pain, or other related complications. CONCLUSION: The mesh-less laparoscopic extraperitoneal linear suspension technique avoids the use of implantable synthetic mesh. It has been shown to lead to favorable postoperative outcomes, considerable patient contentment, and low complication rates. It offers a new, cost-effective treatment option for PHVP patients.


Assuntos
Laparoscopia , Prolapso de Órgão Pélvico , Humanos , Feminino , Procedimentos Cirúrgicos em Ginecologia/métodos , Telas Cirúrgicas/efeitos adversos , Qualidade de Vida , Prolapso de Órgão Pélvico/cirurgia , Resultado do Tratamento , Laparoscopia/métodos
7.
Int Urogynecol J ; 35(3): 713-722, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38430238

RESUMO

INTRODUCTION AND HYPOTHESIS: Fully absorbable implants may be an alternative to permanent meshes in the correction pf pelvic organ prolapse (POP) as they may reduce adverse events by promoting tissue regeneration and collagen metabolism. This study was aimed at evaluating the long-term host and biomechanical response to a fully absorbable poly-4-hydroxybutyrate (P4HB) scaffold in comparison with polypropylene (PP) mesh. METHODS: Poly-4-hydroxybutyrate scaffold (n = 16) and PP mesh (n = 16) were surgically implanted in the posterior vaginal wall of parous female Dohne Merino sheep. Vaginal explants were evaluated in terms of gross necropsy, host response (immune response, collagen deposition, tissue regeneration), biomechanics, and degradation of P4HB at 12 and 24 months post-implantation. RESULTS: Gross necropsy revealed no infection or fluid collection using P4HB or PP. At 12 months, exposures were observed with both P4HB (3 out of 8) and PP (4 out of 8), whereas at 24 months, exposures were observed only with PP (4 out of 8). The tensile stiffness of the P4HB explants was maintained over time despite complete absorption of P4HB. The collagen amount of the vaginal tissue after P4HB implantation increased over time and was significantly higher than PP at 24 months. P4HB scaffolds exhibited significantly lower myofibroblast differentiation than PP meshes at 24 months. CONCLUSIONS: The P4HB scaffold allowed for gradual load transfer to the vaginal wall and resulted in mechanically self-sufficient tissue. P4HB scaffold had a more favorable host response than PP mesh, with higher collagen content, lower myofibroblastic differentiation, and no exposures at 24 months. P4HB scaffolds have potential as an alternative to permanent implants in treating POP.


Assuntos
Prolapso de Órgão Pélvico , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Prolapso de Órgão Pélvico/metabolismo , Vagina/cirurgia , Vagina/metabolismo , Colágeno/metabolismo , Implantes Absorvíveis , Cicatrização , Telas Cirúrgicas/efeitos adversos
8.
Urogynecology (Phila) ; 30(3): 174-180, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484229

RESUMO

IMPORTANCE: There are no current data investigating the relationship between mesh-exposure complications after midurethral sling surgery and antiestrogen therapy. OBJECTIVES: We sought to determine if there are increased mesh-exposure complications between a breast cancer population versus a noncancer population particularly in conjunction with hormone suppression (HS) therapy. STUDY DESIGN: A retrospective chart review was performed on patients with a history of breast cancer undergoing tension-free vaginal tape (TVT) surgery at our institution between 2013 and 2021. A group of patients who underwent TVT surgery without a history of cancer served as our control. Univariate and multivariate logistic regression analyses were performed to identify predictors of mesh exposure complications. RESULTS: One hundred twenty-one patients with breast cancer had TVT surgery. Two hundred ninety-seven patients without cancer had TVT surgery during the same period. Baseline characteristics across all groups were similar. Twenty-nine patients (6.9%) experienced mesh exposure. This occurred at a higher rate in our cancer (15.7%) versus the noncancer population (3.4%). Women with breast cancer taking HS therapy had a higher rate of mesh exposure complications compared with those not taking HS therapy (25.0% versus 6.6%; P = 0.005). The highest rate of mesh exposure complications occurred in the cohort taking estrogen receptor modulators, selective estrogen receptor modulator (10/36 [27.8%]) versus aromatase inhibitors (5/24 [20.8%]) versus no HS therapy (4/61 [6.6%]; P = 0.014). On multivariate analysis, HS therapy use (odds ratio, 1.57; P = 0.007) and diabetes mellitus (odds ratio, 4.53; P = 0.018) were associated with increased TVT-related complications. CONCLUSION: Women with breast cancer had a higher rate of mesh exposure complications from TVT surgery compared with women without cancer, particularly those taking antiestrogenic therapy.


Assuntos
Neoplasias da Mama , Sobreviventes de Câncer , Slings Suburetrais , Humanos , Feminino , Estudos Retrospectivos , Neoplasias da Mama/tratamento farmacológico , Telas Cirúrgicas/efeitos adversos , Slings Suburetrais/efeitos adversos , Moduladores de Receptor Estrogênico/efeitos adversos
9.
Hernia ; 28(2): 637-642, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409571

RESUMO

PURPOSE: Heavyweight polypropylene (HWPP) mesh is thought to increase inflammatory response and delay tissue integration compared to mediumweight (MWPP). Reactive fluid volume (i.e., drain output) may be a reasonable surrogate for integration. We hypothesized that daily drain output is higher with HWPP compared to MWPP in open retromuscular ventral hernia repair (VHR). METHODS: This is a post-hoc analysis of a multicenter, randomized clinical trial conducted March 2017-April 2019 comparing MWPP and HWPP for VHR. Retromuscular drain output in milliliters was measured at 24-h intervals up to postoperative day seven. Univariate analyses compared differences in daily drain output and time to drain removal. Multivariable analyses compared total drain output and wound morbidity within 30 days and hernia recurrence at 1 year. RESULTS: 288 patients were included; 140 (48.6%) HWPP and 148 (51.4%) MWPP. Daily drain output for days 1-3 was higher for HWPP vs. MWPP (total volume: 837.8 mL vs. 656.5 mL) (p < 0.001), but similar on days 4-7 (p > 0.05). Median drain removal time was 5 days for both groups. Total drain output was not predictive of 30-day wound morbidity (p > 0.05) or hernia recurrence at 1 year (OR 1, p = 0.29). CONCLUSION: While HWPP mesh initially had higher drain outputs, it rapidly returned to levels similar to MWPP by postoperative day three and there was no difference in clinical outcomes. We believe that drains placed around HWPP mesh can be managed similarly to MWPP mesh.


Assuntos
Hérnia Ventral , Polipropilenos , Humanos , Telas Cirúrgicas/efeitos adversos , Herniorrafia/efeitos adversos , Hérnia Ventral/cirurgia , Drenagem
10.
Surg Endosc ; 38(4): 1823-1834, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38302758

RESUMO

OBJECTIVES: Seroma represents the most prevalent postoperative complication following laparoscopic inguinal hernia repair, particularly in the case of large inguinoscrotal hernias. This randomized controlled trial was undertaken with the objective of assessing the effects of internal orifice narrowing achieved by suturing the divided distal hernia sac in laparoscopic repair of indirect inguinoscrotal hernias. METHODS: A total of 58 patients aged 18 years or older, were randomized into two groups: Group I, which underwent internal orifice narrowing, and Group II, which served as the control without narrowing. The study's primary endpoint was the incidence and volume of seroma in the inguinal region on postoperative days 1 and 7, as well as at 1, 3, and 6 months following the procedure. Secondary outcomes encompassed metrics like total operative time, acute and chronic pain levels, duration of hospital stay, recurrence rates, and the occurrence of any additional complications. RESULTS: In comparison to the control group, the experimental group exhibited a significantly lower incidence of seroma formation at 7 days (P = 0.001). Furthermore, the ultrasonic assessment indicated a reduced seroma volume in the operative group on postoperative day 7 (8.84 ± 17.71 vs. 52.39 ± 70.78 mL; P < 0.001). Acute pain levels and hospital stay were similar between the two groups (1.22 ± 0.76 vs. 1.04 ± 0.53, P = 0.073; 1.22 ± 0.07 vs. 1.19 ± 0.08, P = 0.627, respectively). Notably, neither chronic pain nor early recurrence, nor any other postoperative complications were observed in either group throughout the follow-up period, which extended for at least 6 months (range: 6-18 months). CONCLUSION: In the context of laparoscopic inguinoscrotal hernia repair, the incidence and volume of seroma can be significantly reduced through the implementation of internal orifice narrowing achieved by suturing the divided distal hernia sac. And, this reduction in seroma formation was not associated elevation in postoperative pain levels or recurrence rates.


Assuntos
Dor Crônica , Hérnia Inguinal , Laparoscopia , Humanos , Dor Crônica/cirurgia , Hérnia Inguinal/cirurgia , Hérnia Inguinal/complicações , Herniorrafia/métodos , Laparoscopia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Recidiva , Seroma/etiologia , Seroma/prevenção & controle , Telas Cirúrgicas/efeitos adversos , Método Duplo-Cego
11.
J Craniomaxillofac Surg ; 52(4): 532-537, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38368208

RESUMO

This study aimed to compare the accuracy of inferomedial orbital fracture restoration using customized orbital implant versus 3D preformed titanium mesh. Patients were divided into two groups. Group 1 underwent surgery with customized orbital implants and intraoperative navigation, while group 2 was treated using 3D preformed titanium meshes with preoperative virtual surgical planning (VSP) and intraoperative navigation. Reconstruction accuracy was assessed by: (1) comparing the postoperative reconstruction mesh position with the preoperative VSP; and (2) measuring the difference between the reconstructed and unaffected orbital volume. Pre- and postoperative diplopia and enophthalmos were also evaluated. Fifty-two patients were enrolled (25 in group 1 vs 27 in group 2). The mean difference between final plate position and ideal digital plan was 0.62 mm (SD = 0.235) in group 1 and 0.69 mm (SD = 0.246) in group 2, with no statistical difference between the groups (p = 0.282). The mean volume differences between the reconstructed and unaffected orbits were 0.95 ml and 1.02 ml in group 1 and group 2, respectively, with no significant difference between the groups (p = 0.860). Overall clinical improvements, as well as complications, were similar. 3D preformed titanium meshes can reconstruct inferomedial fractures with the same accuracy as customized implants. Therefore, in clinical practice, it is recommended to use 3D preformed meshes for this type of fracture due to their excellent results and the potential for reducing time and costs.


Assuntos
Implantes Dentários , Enoftalmia , Fraturas Orbitárias , Implantes Orbitários , Humanos , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/complicações , Implantes Orbitários/efeitos adversos , Titânio , Estudos Retrospectivos , Telas Cirúrgicas/efeitos adversos , Órbita/cirurgia , Enoftalmia/etiologia , Enoftalmia/cirurgia
12.
Medicina (Kaunas) ; 60(2)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38399573

RESUMO

Background: Prospective single and multicenter studies have shown improved outcomes of patients who underwent carotid artery stenting with the novel CGuard dual-layer mesh stent at 1 year. Objectives: The aim of this study is to conduct a systematic review and meta-analysis of all published studies to assess 1-year efficacy and outcomes of CGuard in patients with carotid stenting. Methods: A systematic search was performed. All studies enrolling at least 20 patients were included in our analysis. The primary endpoints were death (all-cause, cardiovascular and ipsilateral stroke-related death) and stroke rate at 1 year. The secondary endpoint was in-stent restenosis at 1 year. Results: The final analysis included 1709 patients. The one-year all-cause mortality rate was 2.97% (39/1699, 95% CI: 1.26-6.86%, I2 = 67%, t2 = 0.3442, p < 0.01), cardiovascular-related death was 0.92% (10/1616, 95% CI: 0.35-2.39%, I2 = 34%, t2 = 0.2302, p = 0.18), and ipsilateral stroke-related death was 0.3% (1/1649, 95% CI: 0.1-0.87%, I2 = 0%, t2 = 0, p = 0.69). The one-year ipsilateral stroke rate was 1.21% (16/1649, 95% CI: 0.58-2.5%, I2 = 28%, t2 = 0.1433, p = 0.23), transient ischemic attacks (TIAs) rate was 1.78% (19/1149, 95% CI: 1.11-2.84%, I2 = 0%, t2 = 0, p = 0.69), and total composite 1-year stroke/TIA rate was 2.97% (32/1149, 95% CI: 1.84-4.77%, I2 = 0%, t2 = 0, p = 0.41). The in-stent restenosis rate at 1 year was 1.06% (13/1653, 95% CI: 0.48-2.34%, I2 = 28%, t2 = 0.2308, p = 0.22). Conclusions: This meta-analysis shows that CAS with CGuard is safe with minimal neurological adverse events and in-stent restenosis rate at 1 year.


Assuntos
Doenças das Artérias Carótidas , Estenose das Carótidas , Reestenose Coronária , Acidente Vascular Cerebral , Humanos , Estenose das Carótidas/complicações , Estenose das Carótidas/cirurgia , Stents/efeitos adversos , Estudos Prospectivos , Telas Cirúrgicas/efeitos adversos , Reestenose Coronária/complicações , Resultado do Tratamento , Doenças das Artérias Carótidas/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Constrição Patológica , Fatores de Risco
13.
Medicine (Baltimore) ; 103(8): e37223, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38394531

RESUMO

INTRODUCTION: Perineal hernia (PH) is a rare complication that can occur after abdominoperineal resection for rectal cancer. Laparoscopic repair of PHs has gained increasing popularity compared to open approaches due to advantages such as superior visualization, decreased invasiveness, and faster recovery. This case report highlights the successful use of laparoscopic tension-free mesh repair for concurrent perineal and inguinal hernias after rectal cancer surgery. CASE DESCRIPTION: A 51-year-old man underwent laparoscopic-assisted abdominoperineal resection for rectal cancer. About 2 months postoperatively, he developed reducible masses in the perineal and left groin regions, associated with urinary symptoms and sensation of prolapse. Physical exam revealed protruding masses that enlarged with Valsalva. Pelvic CT confirmed PH and left inguinal hernia. INTERVENTIONS: Laparoscopic tension-free repair of the PH and inguinal hernia was performed on this patient. The repair was completed by the steps of adhesion separation, mesh placement, and fixation. OUTCOMES: The 98-minute surgery was successful without complications. The patient recovered well, ambulating on postoperative day 2 and getting discharged on day 6. CONCLUSION: This case demonstrates that laparoscopic tension-free repair with mesh is an effective approach for treating PH and concurrent inguinal hernia following rectal cancer surgery, resulting in successful outcomes and low recurrence rates. The laparoscopic technique provides benefits of minimal invasiveness and rapid recovery.


Assuntos
Hérnia Abdominal , Hérnia Inguinal , Laparoscopia , Neoplasias Retais , Masculino , Humanos , Pessoa de Meia-Idade , Hérnia Inguinal/cirurgia , Hérnia Abdominal/cirurgia , Reto/cirurgia , Neoplasias Retais/cirurgia , Laparoscopia/efeitos adversos , Herniorrafia/métodos , Telas Cirúrgicas/efeitos adversos
15.
Hernia ; 28(2): 385-400, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38319440

RESUMO

PURPOSE: Despite advancements in laparoscopic ventral hernia repair (LVHR) using the intraperitoneal onlay mesh technique (sIPOM), recurrence remains a common postoperative complication. The objective of this systematic review and meta-analysis is to compare the efficacy of defect closure (IPOM-plus) versus non-closure in ventral and incisional hernia repair. The aim is to determine which technique yields better outcomes in terms of reducing recurrence and complication rates. METHODS: A comprehensive literature review was conducted in the PubMed, Web of Science, Cochrane Library, Embase, and ClinicalTrials.gov databases from their inception until October 1, 2022, to identify all online English publications that compared the outcomes of laparoscopic ventral hernia repair with and without fascia closure. RESULTS: Three randomized controlled trials (RCTs) and eleven cohort studies involving 1585 patients met the inclusion criteria. The IPOM-plus technique was found to reduce the recurrence of hernias (OR = 0.51, 95% CI [0.35, 0.76], p < 0.01), seroma (OR = 0.48, 95% CI [0.32, 0.71], p < 0.01), and mesh bulging (OR = 0.08, 95% CI [0.01, 0.42], p < 0.01). Subgroup analysis revealed that body mass index (BMI) (OR = 0.43, 95% CI [0.29, 0.65], p < 0.0001), type of article (OR = 0.51, 95% CI [0.35, 0.76], p = 0.0008 < 0.01), geographical location (OR = 0.54, 95% CI [0.36, 0.82], p = 0.004 < 0.01), follow-up time (OR = 0.50, 95% CI [0.34, 0.73], p = 0.0004 < 0.01) had a significant influence on the postoperative recurrence of the IPOM-plus technique. CONCLUSION: The IPOM-plus technique has been shown to greatly reduce the occurrence of recurrence, seroma, and mesh bulging. Overall, the IPOM-plus technique is considered a safe and effective procedure. However, additional randomized controlled studies with extended follow-up periods are necessary to further evaluate the IPOM-plus technique.


Assuntos
Hérnia Ventral , Hérnia Incisional , Laparoscopia , Humanos , Fáscia , Hérnia Ventral/cirurgia , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Hérnia Incisional/cirurgia , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Recidiva , Seroma/etiologia , Seroma/epidemiologia , Telas Cirúrgicas/efeitos adversos
16.
Hernia ; 28(2): 575-584, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38345668

RESUMO

PURPOSE: Use of biologic or synthetic mesh in hernia repair shifts is based on evolving evidence. Poly-4-hydroxybutyrate (P4HB) biosynthetic mesh is a potential alternative to biologic and synthetic mesh in ventral hernia repair (VHR). This meta-analysis assesses the efficacy of P4HB mesh in clean and contaminated surgical settings. METHODS: Two authors searched literature on PubMed, reviewing titles and abstracts of all articles to determine inclusion eligibility. Post-operative data were compared via transformation method to convert the proportion of patients with the outcome of interest into a suitable quantity for random-effects synthesis using STATA software. RESULTS: Initial search yielded 287 citations. Six studies were included and categorized on whether hernia repairs were conducted in clean (CDC class I) or contaminated cases (CDC class II-IV). The pooled proportion of surgical site infection (SSI), surgical site occurrence (SSO), hernia recurrence, total surgical complications, and reoperation were calculated in 391 clean and 81 contaminated cases. For clean vs. contaminated cases, the following pooled proportions were noted: SSI (2% (CI 0-7%) vs 9% (CI 0-025) (p = 0.03), SSO: 14% (CI 5-25%) vs 35% (CI 22-50%) (p = 0.006), hernia recurrence (8% (CI 1-19%) vs 4% (CI 0-12%) (p = 0.769); surgical complications (17% (CI 6-32%) vs 50% (CI 27-72%) (p = 0.009). Reoperation data were available in 298 clean cases across four studies: 5% (CI 0-15%). CONCLUSIONS: P4HB biosynthetic mesh may be more effective than previously thought, particularly in clean wounds. P4HB may also be superior to biologic mesh when compared to clinical trial data. Further research is necessary for more direct comparison.


Assuntos
Produtos Biológicos , Hérnia Ventral , Humanos , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Resultado do Tratamento , Telas Cirúrgicas/efeitos adversos , Implantes Absorvíveis , Infecção da Ferida Cirúrgica/cirurgia , Hérnia Ventral/cirurgia , Hérnia Ventral/complicações , Hidroxibutiratos , Recidiva , Estudos Retrospectivos
17.
Surg Endosc ; 38(4): 2019-2026, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38424284

RESUMO

INTRODUCTION: Intraperitoneal onlay mesh (IPOM) placement for small to medium-sized hernias has garnered negative attention due to perceived long-term risk of mesh-related complications. However, sparse data exists supporting such claims after minimally invasive (MIS) IPOM repairs and most is hindered by the lack of long-term follow-up. We sought to report long-term outcomes and mesh-related complications of MIS IPOM ventral hernia repairs. METHODS AND PROCEDURES: Adult patients who underwent MIS IPOM ventral hernia repair at our institution were identified in the Abdominal Core Health Quality Collaborative database from October 2013 to October 2020. Outcomes included hernia recurrence and mesh-related complications or reoperations up to 6 years postoperatively. RESULTS: A total of 325 patients were identified. The majority (97.2%) of cases were elective, non-recurrent (74.5%), and CDC class I (99.4%). Mean hernia width was 4.16 ± 3.86 cm. Median follow-up was 3.6 (IQR 2.8-5) years. Surgeon-entered or patient-reported follow-up was available for 253 (77.8%) patients at 3 years or greater postoperatively. One patient experienced an early small bowel obstruction and was reoperated on within 30 days. Two-hundred forty-five radiographic examinations were available up to 6 years postoperatively. Twenty-seven patients had hernia recurrence on radiographic examination up to 6 years postoperatively. During long-term follow-up, two mesh-related complications required reoperations: mesh removed for chronic pain and mesh removal at the time of colon surgery for perforated cancer. Sixteen additional patients required reoperation within 6 years for the following reasons: hernia recurrence (n = 5), unrelated intraabdominal pathology (n = 9), obstructed port site hernia (n = 1), and adhesive bowel obstruction unrelated to the prosthesis (n = 1). The rate of reoperation due to intraperitoneal mesh complications was 0.62% (2/325) with up to 6 year follow-up. CONCLUSION: Intraperitoneal mesh for repair of small to medium-sized hernias has an extremely low rate of long-term mesh-related complications. It remains a safe and durable option for hernia surgeons.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Hérnia Ventral , Hérnia Incisional , Obstrução Intestinal , Laparoscopia , Adulto , Humanos , Telas Cirúrgicas/efeitos adversos , Hérnia Ventral/cirurgia , Herniorrafia/efeitos adversos , Próteses e Implantes , Obstrução Intestinal/cirurgia , Hérnia Incisional/cirurgia , Recidiva
19.
Biomater Adv ; 159: 213800, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38377947

RESUMO

Currently, in vitro testing examines the cytotoxicity of biomaterials but fails to consider how materials respond to mechanical forces and the immune response to them; both are crucial for successful long-term implantation. A notable example of this failure is polypropylene mid-urethral mesh used in the treatment of stress urinary incontinence (SUI). The mesh was largely successful in abdominal hernia repair but produced significant complications when repurposed to treat SUI. Developing more physiologically relevant in vitro test models would allow more physiologically relevant data to be collected about how biomaterials will interact with the body. This study investigates the effects of mechanochemical distress (a combination of oxidation and mechanical distention) on polypropylene mesh surfaces and the effect this has on macrophage gene expression. Surface topology of the mesh was characterised using SEM and AFM; ATR-FTIR, EDX and Raman spectroscopy was applied to detect surface oxidation and structural molecular alterations. Uniaxial mechanical testing was performed to reveal any bulk mechanical changes. RT-qPCR of selected pro-fibrotic and pro-inflammatory genes was carried out on macrophages cultured on control and mechanochemically distressed PP mesh. Following exposure to mechanochemical distress the mesh surface was observed to crack and craze and helical defects were detected in the polymer backbone. Surface oxidation of the mesh was seen after macrophage attachment for 7 days. These changes in mesh surface triggered modified gene expression in macrophages. Pro-fibrotic and pro-inflammatory genes were upregulated after macrophages were cultured on mechanochemically distressed mesh, whereas the same genes were down-regulated in macrophages exposed to control mesh. This study highlights the relationship between macrophages and polypropylene surgical mesh, thus offering more insight into the fate of an implanted material than existing in vitro testing.


Assuntos
Telas Cirúrgicas , Incontinência Urinária por Estresse , Humanos , Teste de Materiais , Telas Cirúrgicas/efeitos adversos , Polipropilenos/química , Materiais Biocompatíveis , Macrófagos , Incontinência Urinária por Estresse/cirurgia
20.
Hernia ; 28(2): 615-620, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38374213

RESUMO

PURPOSE: Inguinal hernia is a common complication of peritoneal dialysis (PD). Although tension-free mesh repair is a leading option for inguinal hernia repair, concerns over serious mesh-related complications may indicate a role for non-mesh inguinal hernia repair. In addition, there is no consensus on the perioperative dialysis regimen. Early resumption of PD may avoid the additional risks associated with hemodialysis. We report on the outcomes of non-mesh inguinal hernia repair in patients on continuous ambulatory PD (CAPD) and provide a perioperative dialysis protocol that aims to guide early resumption of PD. METHODS: Between May 2019 and September 2023, thirty CAPD patients with 43 inguinal hernias who underwent non-mesh inguinal hernia repair were retrospectively analyzed. Data on the patient characteristics, perioperative dialysis regimen, perioperative features, complications, and hernia recurrence were collected and assessed. RESULTS: Thirty patients with a total of 43 inguinal hernia repairs were included in this study. The median age was 53 years. 23 patients were male and 7 were female. Non-mesh inguinal repair was performed for all patients. PD was resumed at a median of 2 days after the surgery. Five patients received interim hemodialysis. There were no postoperative surgical or uremic complications and no recurrence after a median follow-up of 31.5 months. CONCLUSION: Our study demonstrates the effectiveness and safety of non-mesh repair with early resumption of PD in patients on CAPD. Interim HD is unnecessary in selected patients. Choosing the optimal perioperative dialysis regimen is essential to managing inguinal hernias in CAPD patients.


Assuntos
Hérnia Inguinal , Diálise Peritoneal Ambulatorial Contínua , Diálise Peritoneal , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Hérnia Inguinal/cirurgia , Hérnia Inguinal/etiologia , Diálise Peritoneal Ambulatorial Contínua/efeitos adversos , Estudos Retrospectivos , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Telas Cirúrgicas/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...